Sensaphone FGD-1800-CD Monitoring System with NEMA 4X Clear Door Enclosure, 8 Inputs
- Part #:FGD-1800-CD
- Model #:1800
- Condition:Brand New

Overview
The Sensaphone FGD-1800-CD Monitoring System with NEMA 4X Clear Door Enclosure is an industrial-grade facility monitoring device designed for reliable remote oversight of critical environmental and equipment conditions. This standalone voice-dialing unit monitors temperature, humidity, water leaks, equipment contacts, and more through eight supervised inputs. Its rugged NEMA 4X enclosure protects internal electronics in harsh or corrosive environments, making it well-suited for greenhouses, agriculture sites, mechanical rooms, pump houses, and remote buildings requiring dependable alarm reporting.
When an abnormal condition is detected, the FGD-1800 automatically dials up to eight phone numbers with a customizable voice alert, ensuring rapid notification even in locations without internet connectivity. Compared to cloud-based systems, this telephone auto-dialer provides independent, infrastructure-free alarm reporting that continues functioning during network outages. Its long-tail reliability and ability to monitor multiple sensor types give users a cost-effective solution for standalone environmental protection.
The system accepts temperature, humidity, dry contact, and 4–20 mA industrial sensors, offering flexible integration across diverse facility environments. Configuration is stored in nonvolatile memory so programming and logs remain intact through power interruptions. Users can call into the device at any time to hear real-time status reports for each monitored condition. This makes the FGD-1800-CD an excellent choice for operators who need durable, voice-alert-based facility monitoring without dependence on cloud platforms.
Key Features
- NEMA 4X enclosure shields electronics from moisture, dust, and corrosive environments.
- Eight supervised inputs support temperature, humidity, water detection, and equipment monitoring.
- Voice auto-dialing alerts notify up to eight contacts via standard telephone lines.
- Custom voice messages allow personalized alarm recordings for clear communication.
- 4–20 mA compatibility enables integration with third-party industrial sensors.
- Nonvolatile memory preserves programming and logs during power failures.
- Relay output can activate local devices automatically in alarm conditions.
Specifications
Function: Remote environmental and equipment monitoring via voice auto-dialing
Materials: Electronics inside NEMA 4X polycarbonate enclosure
Dimensions: N/A
Performance: Eight supervised inputs with programmable voice alerts to eight contacts
Weight: N/A
Origin: N/A
Style: Standalone industrial monitoring and alarm dialer
Compliance: NEMA 4X enclosure rating
Applications
This system is ideal for technicians, growers, facilities managers, and maintenance personnel who require independent, telephone-based facility monitoring without cloud dependencies. Its rugged enclosure and reliable alarm reporting deliver long-tail performance across demanding, remote, or moisture-prone environments.
- Greenhouses and agricultural buildings needing reliable environmental alarm reporting.
- Pump houses, well systems, and remote utility rooms lacking internet access.
- Mechanical and boiler rooms requiring temperature or water detection monitoring.
- Food storage and warehouse locations sensitive to environmental changes.
- Small industrial sites requiring independent facility monitoring and voice alerts.
Performance and Characteristics
The FGD-1800 provides reliable environmental monitoring through eight supervised inputs, reducing false alarms and ensuring consistent sensor integrity. Its voice auto-dialing system offers significantly faster notification than manual checks and operates independently of cloud platforms. The NEMA 4X enclosure improves durability by up to 300% compared to non-rated housings, protecting internal electronics in wet, dusty, or chemical environments. Custom voice messaging improves clarity during alerts, reducing response time in critical conditions.
Additional Information
This model supports dry contact, 2.8K thermistor, and 4–20 mA sensors, enabling broad industrial compatibility. Users can call into the system to hear live condition status, ensuring continuous visibility even when off-site. The relay output can activate pumps, fans, or alarms automatically in response to triggered events.
Kit Contents
- Sensaphone FGD-1800-CD Monitoring System
- NEMA 4X clear-door enclosure
- Power supply
- Mounting hardware
- User documentation
Call to Action
Protect critical environments with dependable voice-based alarm monitoring—upgrade to the Sensaphone FGD-1800-CD today.
- Specification Sheet
- You May Also Like
- Your Recently Viewed
- Reviews
- Q&A
| Communication Method | Phone Line |
| Number of Inputs | 8 |
| Input Types | Contact, 2.8k, 10k, 4-20mA |
| Temperature Sensing Range | -109° to 168°F |
| Local Access | Keypad and speaker for local programming, Easy voice prompted programming, Password Protected, Recent alarm history playback, LEDs |
| Alarm Notification | Eight custom voice phone calls |
| Power Supply | Plug in power supply also monitors for power failures, Internal battery backup |
| Physical (1800) | 8.0 x 12.3 x 5.6, 6lbs |
| Warranty | 2 Years |