PCE Instruments PCE-PA 8000 3-Phase-Power-Analyser, up to 600 V
- Part #:PCE-PA 8000
- Condition:Brand New






The PCE Instruments PCE-PA 8000 3-Phase Power Analyzer is a high-precision diagnostic instrument for detailed analysis and recording of electrical parameters in single-phase and three-phase systems. Engineered for industrial, commercial, and energy-audit applications, it provides professional-grade accuracy and reliability.
With measurement capability up to 600 V and 1200 A, the PCE-PA 8000 delivers a complete evaluation of power, phase angle, and power factor. Its integrated data logging system stores results directly to an SD card, streamlining performance monitoring and system optimization. Keyword: electrical testing instrument.
Built for safety and compliance, this analyzer meets IEC 1010 and CAT III 600V standards, ensuring dependable operation in demanding environments. Professionals rely on the PCE-PA 8000 for accurate, repeatable readings and intuitive data visualization through its large LCD display. Keyword: industrial power measurement tool.
Key Features
- Comprehensive Power Analysis: Measures active, apparent, and reactive power, voltage, current, phase angle, and power factor (keyword: power analyzer functions).
- Data Logging: Records directly to an SD card in XLS format for easy data review (keyword: power analyzer with data logger).
- Wide Measurement Range: Supports up to 600 V and 1200 A inputs (keyword: high-range power analyzer).
- Large LCD Display: 3.7-inch (94 mm) screen for clear real-time readings (keyword: professional display analyzer).
- Safety Standards Compliance: Meets IEC 1010 and CAT III 600V safety standards (keyword: CAT III rated instrument).
Specifications
Model Number: PCE-PA 8000
Voltage Range: 10 V – 600 V
Current Range: 20 A – 1200 A
Data Storage: 2 GB SD card (XLS format)
Display: 3.7-inch (94 mm) LCD
Power Supply: 9 V DC mains adapter or 8 × 1.5 V AA batteries
Safety Rating: IEC 1010, CAT III 600V
Applications
Engineered for professional use in diagnostics, maintenance, and energy optimization, the PCE-PA 8000 is a versatile measurement tool for technicians and engineers.
- Electrical Troubleshooting: Monitor and analyze circuit loads and imbalances (long-tail keyword: 3-phase power analyzer for electricians).
- Energy Audits: Identify inefficiencies and optimize system performance.
- Industrial Maintenance: Evaluate motors, generators, and power distribution systems.
- Power Quality Analysis: Detect harmonics, unbalanced loads, and phase faults.
Performance and Characteristics
The PCE-PA 8000 delivers highly accurate power metrics for critical analysis of voltage, current, and phase relationships. Compared to basic multimeters, its three-phase measurement capability and built-in data logger enable continuous, unattended monitoring. The rugged design ensures stable readings even in high-interference environments, while the SD card export feature simplifies detailed reporting.
Kit Contents
- 1 × PCE-PA 8000 Clamp Meter
- 3 × Current Clamps
- 4 × Test Cables
- 4 × Alligator Clips
- 1 × 2 GB SD Card
- 1 × 9 V DC Mains Adapter
- 8 × 1.5 V AA Batteries
- 1 × Carrying Case
Additional Information
The PCE-PA 8000 supports single-phase, three-phase, and four-wire configurations with an integrated timer and calendar for scheduled logging. Measurement precision varies by range and parameter. This analyzer simplifies data management and enhances workflow efficiency for field technicians and energy auditors alike.
Call to Action
Optimize your electrical diagnostics — get the PCE-PA 8000 3-Phase Power Analyzer today for precision, safety, and efficiency in every test.
WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov- You May Also Like
- Your Recently Viewed
- Reviews
- Q&A
| Voltage (AC V) | ||
| Measurement range | Resolution | Accuracy |
| 10 V ... 600 V (phase to neutral) | 0.1 V | ±(0.5 % + 0.5 V) |
| 10 V ... 600 V (phase to neutral) | ||
| Current (AC A) | ||
| Measurement range | Resolution | Accuracy |
| 20 A | 0.001 A (< 10 A) 0.01 A (≥ 10 A) | ±(0.5 % + 0.1 V) |
| 200 A | 0.01 A (< 100 A) 0.1 A (≥ 100 A) | ±(0.5 % + 0.5 A) |
| 1200 A | 0.1 A (< 1000 A) 1 A (≥ 1000 A) | ±(0.5 A + 5 A) |
| Active power | ||
| Measurement range | Resolution | Accuracy |
| 0 KW ... 9.999 KW | 0.001 KW | ±(1 % + 0.008 KW) |
| 10 KW ... 99.99 KW | 0.01 KW | ±(1 % + 0.008 KW) |
| 100 KW ... 999.9 KW | 0.1 KW | ±(1 % + 0.8 KW) |
| 1 MW ... 9.999 MW | 0.001 MW | ±(1 % + 0.008 MW) |
| Apparent power | ||
| Measurement range | Resolution | Accuracy |
| 0 KVA ... 9.999 KVA | 0.001 KVA | ±(1 % + 0.008 KVA) |
| 10 KVA ... 99.99 KVA | 0.01 KVA | ±(1 % + 0.08 KVA) |
| 100 KVA ... 999.9 KVA | 0.1 KVA | ±(1 % + 0.8 KVA) |
| 1 MVA ... 9.999 MVA | 0.001 MVA | ±(1 % + 0.008 MVA) |
| Reactive power | ||
| Measurement range | Resolution | Accuracy |
| 0 KVAR ... 9.999 KVAR | 0.001 KVAR | ±(1 % + 0.008 KVAR) |
| 10 KVAR ... 99.99 KVAR | 0.01 KVAR | ±(1 % + 0.08 KVAR) |
| 100 KVAR ... 999.9 KVAR | 0.1 KVAR | ±(1 % + 0.8 KVAR) |
| 1 MVAR ... 9.999 MVAR | 0.001 MVAR | ±(1 % + 0.008 MVAR) |
| Active energy | ||
| Measurement range | Resolution | Accuracy |
| 0 KWh ... 9.999 KWh | 0.001 KWh | ±(1 % + 0.008 KWh) |
| 10 KWh ... 99.99 KWh | 0.01 KWh | ±(1 % + 0.08 KWh) |
| 100 KWh ... 999.9 KWh | 0.1 KWh | ±(1 % + 0.8 KWh) |
| 1 MWh... 9.999 MWh | 0.001 MWh | ±(1 % + 0.008 MWh) |
| Apparent energy | ||
| Measurement range | Resolution | Accuracy |
| 0 KVAh ... 9.999 KVAh | 0.001 KVAh | ±(2 % + 0.008 KVAh) |
| 10 KVAh ... 99.99 KVAh | 0.01 KVAh | ±(2 % + 0.08 KVAh) |
| 100 KVAh ... 999.9 KVAh | 0.1 KVAh | ±(2 % + 0.8 KVAh) |
| 1 MVAh... 9.999 MVAh | 0.001 MVAh | ±(2 % + 0.008 MVAh) |
| Reactive energy | ||
| Measurement range | Resolution | Accuracy |
| 0 KVARh ... 9.999 KVARh | 0.001 KVARh | ±(2 % + 0.008 KVARh) |
| 10 KVARh ... 99.99 KVARh | 0.01 KVARh | ±(2 % + 0.08 KVARh) |
| 100 KVARh ... 999.9 KVARh | 0.1 KVARh | ±(2 % + 0.8 KVARh) |
| 1 MVARh... 9.999 MVARh | 0.001 MVARh | ±(2 % + 0.008 MVARh) |
| Power factor | ||
| Measurement range | Resolution | Accuracy |
| 0 ... 1 | 0.01 | ±0.04 |
| Phase angle | ||
| Measurement range | Resolution | Accuracy |
| -180º ... 180º | 0.1º | ±1º |
| Frequency | ||
| Measurement range | Resolution | Accuracy |
| 45 Hz ... 65 Hz | 0.1 Hz | 0.1 Hz |
| General specifications | ||
| Display | 3.7 in / 94.0 mm LCD (320 x 240 pixels) with LED backlight | |
| Electrical properties | AC V, AC A, active power, apparent power, power factor, phase angle, mains frequency | |
| Voltage ranges | 10 V ... 600 V AC, automatic range selection | |
| Security / Standards | IEC1010CAT III 600V | |
| AC V input resistance | 10 MΩ | |
| Operation frequency of current clamps | 40 Hz ... 1 kHz | |
| Tested operation frequency of current clamps | 45 Hz ... 65 Hz | |
| Overload protection | AC V / 720 V rms | |
| AC A | 1300 A with current clips | |
| Memory | SD card up to 16 GB | |
| Measurement display rate | 1 second | |
| Data logger | SD | |
| Measurement sample rate | 2 seconds... 7200 seconds | |
| Data output | USB or RS-232, depending on the connection cable | |
| Operating temperature | 0º C ... 50º C / 32° F ... 122° F | |
| Operating humidity | < 80 % H.r. | |
| Power | 8 x 1.5 V AA batteries / mains component | |
| Input current | Meter: 300 mA DC Clamp: 34 mA DC | |
| Max. diameter | 50 mm / 1.9 in | |
| Weight | Meter: 948 g / 33.4 oz (with batteries) Clip: 467 g / 16.4 oz (with cable) | |
| Dimensions | Meter: 225 mm x 125 mm x 64 mm / 8.8 in x 4.9 in x 2.5 in | |
| Clamp: 210 mm x 64 mm x 33 mm / 8.2 in x 2.5 in x 1.2 in | ||
| Jaw: 86 mm / 3.3 in (exterior) | ||
Leave a review of this product!
If you've used this product, please leave a review to tell us and other customers what you thought about it. Get paid up to $16 for submitting one of the first text, photo, or video reviews for this item. Please contact us for more details.
Write a text review
Earn $2.00Post a product photo
Earn $4.00Post a product video
Earn $10.00