Misco PA203X-001-006-008-016-018 Digital Fire Sprinkler Refractometer for Glycol Antifreeze Testing
- Part #:PA203X-001-006-008-016-018
- Condition:Brand New





Key Facts
- Digital handheld refractometer designed for fire sprinkler antifreeze testing applications
- Measures propylene glycol concentration, glycerine concentration, freeze point, and refractive index
- Automatic temperature compensation from 0 degrees C to 50 degrees C
- Dual-line LCD display with simple two-button operation
- Supports propylene glycol and glycerine freeze point analysis in degrees F
- Automatic water calibration for simplified setup and verification
- Portable laboratory-style testing instrument for field service and inspections
- Designed for fire sprinkler system maintenance and freeze protection verification
Overview
The Misco PA203X-001-006-008-016-018 Fire Sprinkler Refractometer is a fourth-generation digital handheld refractometer designed for testing antifreeze solutions used in fire sprinkler and fire suppression systems. This instrument measures propylene glycol concentration, glycerine concentration, freeze point protection levels, and refractive index values for accurate system analysis.
This digital refractometer helps fire protection professionals verify proper antifreeze concentration levels within sprinkler systems to support freeze protection and system reliability. The handheld design allows convenient field testing during inspections, maintenance procedures, and system servicing operations.
The instrument includes automatic temperature compensation, automatic calibration with water, and a large dual-line LCD display for clear digital readings in varying environmental conditions.
Product images are for reference only and may vary.
Features
- Measures propylene glycol percentage concentration
- Measures propylene glycol freeze point in degrees F
- Measures glycerine percentage concentration
- Measures glycerine freeze point in degrees F
- Measures refractive index (nD20) for premix analysis
- Automatic temperature compensation for improved measurement consistency
- Portable handheld digital design for field testing
- Dual-line LCD display for easy reading
- Simple two-button operation
- Automatic calibration using water
Technical Specifications
- Manufacturer: Misco
- Model Number: PA203X-001-006-008-016-018
- Instrument Type: Digital Handheld Refractometer
- Display Type: Dual-line LCD
- Temperature Compensation: Automatic
- Temperature Compensation Range: 0 degrees C to 50 degrees C
Propylene Glycol Percentage Scale (Scale 006)
- Units: Percent v/v
- Measurement Range: 0 to 100 percent
- Resolution: 0.1
- Precision: 0.1
Propylene Glycol Freeze Point Scale (Scale 008)
- Units: Freeze Point Degrees F
- Measurement Range: +32 degrees F to -60 degrees F
- Resolution: 1 degree
- Precision: 2 degrees
Glycerine Percentage Scale (Scale 016)
- Units: Percent v/v
- Measurement Range: 0 to 100 percent
- Resolution: 0.1
- Precision: 0.1
Glycerine Freeze Point Scale (Scale 018)
- Units: Freeze Point Degrees F
- Measurement Range: +32 degrees F to -46 degrees F
- Resolution: 1 degree
- Precision: 1 degree
Refractive Index Scale (Scale 001)
- Units: Refractive Index (nD20)
- Measurement Range: 1.3330 to 1.5000
- Resolution: 0.0001
- Precision: 0.0001
Use Cases
- Fire sprinkler system antifreeze testing
- Freeze protection verification for fire suppression systems
- Commercial building sprinkler maintenance inspections
- Industrial fire suppression system servicing
- Facility maintenance and safety compliance programs
- HVAC and mechanical contractor antifreeze testing applications
- Verification of premixed antifreeze solution concentration
- Routine preventive maintenance for freeze-sensitive piping systems
What’s Included
- Misco digital fire sprinkler refractometer
Performance and Characteristics
This handheld digital refractometer is designed to provide accurate freeze point and concentration measurements for fire sprinkler antifreeze solutions. The automatic temperature compensation system helps maintain consistent readings during field use across varying ambient conditions.
The digital LCD interface minimizes reading interpretation errors compared to analog refractometers, while the portable construction supports on-site testing and maintenance workflows.
Installation Notes
- Calibrate the refractometer with water before use according to manufacturer procedures
- Clean the prism surface after each test sample
- Use only compatible sample liquids intended for the supported scales
- Store the instrument in a clean and dry environment when not in use
Category FAQs
What does this refractometer measure?
This instrument measures propylene glycol concentration, glycerine concentration, freeze point protection levels, and refractive index values for fire sprinkler antifreeze solutions.
Why is antifreeze testing important in fire sprinkler systems?
Proper antifreeze concentration helps support freeze protection in fire sprinkler piping systems exposed to low temperatures. Incorrect concentration levels may reduce system performance or freeze protection capability.
Does this refractometer include automatic temperature compensation?
Yes. The instrument includes automatic temperature compensation from 0 degrees C to 50 degrees C to help maintain measurement consistency.
Can this refractometer test both propylene glycol and glycerine solutions?
Yes. The device includes dedicated scales for both propylene glycol and glycerine concentration and freeze point analysis.
What is the benefit of a digital refractometer?
Digital refractometers provide clear numeric readings that can help reduce interpretation errors compared to manual optical refractometers.
Can this unit measure refractive index?
Yes. The refractometer includes an nD20 refractive index measurement scale for premix solution analysis.
Who commonly uses fire sprinkler refractometers?
These instruments are commonly used by fire protection contractors, sprinkler inspection professionals, facility maintenance teams, and industrial fire suppression technicians.
Is this suitable for field service work?
Yes. The handheld portable design is intended for on-site testing and maintenance applications.
WARNING: Cancer and Reproductive Harm www.P65Warnings.ca.gov- Accessories
- You May Also Like
- Your Recently Viewed
- Reviews
- Q&A
| Optic Material | Sapphire |
| Detector Elements | 1,024 |
| Well/Sample Area Material | Stainless Steel |
| Evaporation Cover | YES |
| Light Source | Precision LED at 589 nm |
| Display Type | LCD |
| Display Characters | 24 Characters - 2 Lines |
| Display Backlight | YES |
| Display Language | English, German, Spanish, French, Italian, Russian |
| Temperature Range | Scale Dependent 0 to 50 °C (32 to 122 °F) Typical |
| Temp. Control Method | Auto Temp. Correction |
| Temp. Control Basis | Scale Dependent |
| Power Source | 2 AAA Batteries |
| Battery Life | Approx. 5,000 Readings |
| Body Color | BLUE (2-Tone) |
| Body Material | Polymer |
| Water Resistance | IP65 - Low Pressure Water |
| Dimensions | 5.7 x 2.95 x 1.46 in. (145 x 75 x 37 mm) |
| Weight | 8.8 Oz. (250 grams) |
| User Programmable | Options/Settings, Select Scale |
| User Calibration Points | Two |
| Error Codes | Text Based |
| Approvals/Certifications | CE |
| Country of Origin | USA |
Leave a review of this product!