Technical details
"m.v." - measured value1-phase power quality recorderThe device is designed to work with mains:
*
Measurement functions | Measurement range | Display range | Resolution | Accuracy |
---|---|---|---|---|
Fault loop impedance | ||||
Fault loop ZL-PE, ZL-N, ZL-L | 0.13 Ω ... 1999.9 Ω acc. to IEC 61557 | 0,00 Ω ... 1999 Ω | from 0.001 Ω | from ±(5% m.v. + 0.03 Ω) |
Fault loop ZL-PEin RCD mode | from 0.50 Ω ... 1999 Ω acc. to IEC 61557 | 0,00 Ω ... 1999 Ω | from 0.01 Ω | from ±(6% m.v. + 5 digits) |
Measurements of RCD parameters | ||||
RCD tripping test and measurement of tripping time tAmeasuring current 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn | ||||
general and short-time delay RCD | ||||
TN / TT mains | 0 ms ... 300 ms | 0 ms ... 300 ms | 1 ms | ±(2% m.v. + 2 digits) |
selective RCD | 0 ms ... 500 ms | 0 ms ... 500 ms | 1 ms | ±(2% m.v. + 2 digits) |
Measurement of RCD tripping current IAmeasuring current 0.2 IΔn ... 2.0 IΔn | ||||
for sinusoidal residual current (AC type) | 3.3 mA ... 1000 mA | 3.3 mA ... 1000 mA | from 0.1 mA | ±5% IΔn |
for unidirectional residual current and unidirectional with the 6 mA DC bias (type A) | 3.5 mA ... 700 mA | 3.5 mA ... 700 mA | from 0.1 mA | ±10% IΔn |
for direct residual current (type B) | 2.0 mA ... 1000 mA | 2.0 mA ... 1000 mA | from 0.1 mA | ±10% IΔn |
Earth resistance | ||||
3- and 4-pole method | from 0.50 Ω ... 1.99 kΩ acc. to IEC 61557-5 | 0.00 Ω ... 1.99 kΩ | from 0.01 Ω | from ±(2% m.v. + 3 digits) |
3-pole + clamp method | 0.00 Ω ... 1.99 kΩ | 0.00 Ω ... 1.99 kΩ | from 0.01 Ω | ±(8% m.v. + 4 digits) |
2-clamp method | 0.00 Ω ... 99.9 kΩ | 0.00 Ω ... 99.9 kΩ | from 0.01 Ω | from ±(10% m.v. + 4 digits) |
Resistance-to-earth | 0.0 Ωm ... 99.9 kΩm | 0.0 Ωm ... 99.9 kΩm | from 0.1 Ωm | Depending on accuracy of REmeasurement |
Insulation resistance | ||||
Measuring voltage 50 V | 50 kΩ ... 250 MΩ acc. to IEC 61557-2 | 0 kΩ ... 250 MΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 100 V | 100 kΩ ... 500 MΩ acc. to IEC 61557-2 | 0 kΩ ... 500 MΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 250 V | 250 kΩ ... 999 MΩ acc. to IEC 61557-2 | 0 kΩ ... 999 MΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 500 V | 500 kΩ ... 2.00 GΩ acc. to IEC 61557-2 | 0 kΩ ... 2.00 GΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 1000 V | 1000 kΩ ... 9.99 GΩ acc. to IEC 61557-2 | 0 kΩ ... 9.99 GΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Resistance of protective conductors and equipotential bondings | ||||
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current | 0.12 Ω ... 400 Ω acc. to IEC 61557-4 | 0.00 Ω ... 400 Ω | from 0.01 Ω | ±(2% m.v. + 3 digits) |
Measurement of resistance with low current | 0.0 Ω ... 1999 Ω | 0.0 Ω ... 1999 Ω | from 0.1 Ω | ±(3% m.v. + 3 digits) |
Light intensity | ||||
Measurement in luxes (lx) | 0 lx ... 399.9 klx | 0 lx ... 399.9 klx | from 0.001 lx | from ±(2% m.v. + 5 digits) |
Measurement in feet-candles (fc) | 0 fc ... 39.99 kfc | 0 fc ... 39.99 kfc | from 0.001 fc | from ±(2% m.v. + 5 digits) |
Phase sequence indication | in the same direction (correct), opposite direction (incorrect), UL-Lvoltage: 95 V ... 500 V (45 Hz ... 65 Hz) |
- with nominal frequency 50/60 Hz
- with nominal voltage: 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V
- single-phase
Parameter | Measuring range | Max. resolution | Accuracy |
---|---|---|---|
Alternating voltage (TRMS) | 0.0 ... 500 V | 0.1 V | from ±(2% m.v. + 2 digits) |
Alternating current (TRMS) | depending on clamp* | 0.1 mA | from ±(5% m.v. + 3 digits) (error does not account for clamp error) |
Frequency | 45.0 ... 65.0 Hz | 0.1 Hz | ±(0.1% m.v. + 1 digit) |
Active, reactive, apparent and distortion power | 0 VA ... 1.5 MVA, 0 W ... 1.5 MW, 0 var ... 1.5 Mvar | 1 VA, 1 W, 1 var | from ±(7% m.v. + 3 digits) |
cosφ and power factor (PF) | 0.00 ... 1.00 | 0.01 | unspecified |
Harmonics | |||
Voltage | 0.0 ... 500 V | 0.1 V | from ±(5% m.v. + 3 digits) |
Current | depending on clamp* | as for alternating current True RMS | from ±(5% m.v. + 3 digits) (error does not account for clamp error) |
THD | |||
Voltage | 0.0 ... 999.9% (in relation to the first harmonic) | 0.1% | ±5% |
Current | 0.0 ... 999.9% (in relation to the first harmonic) | 0.1% | ±5% (error does not account for clamp error) |
- F-1A, F-2A, F-3A clamp : 0 ... 3000 A AC (10 000 Ap-p)
- C-3 clamp: 0 ... 1000 A AC (3600 Ap-p)
- C-6A clamp: 0..10 A AC (36 Ap-p)