- Technical details
- Description
- You May Also Like
- Your Recently Viewed Items
- Reviews
Technical details
"m.v." - measured value
Measurement functions | Measurement range | Display range | Resolution | Accuracy |
---|---|---|---|---|
Fault loop impedance | ||||
Fault loop ZL-PE, ZL-N, ZL-L | 0.13 Ω ... 1999.9 Ω acc. to IEC 61557 | 0.00 Ω ... 1999 Ω | from 0.01 Ω | ±(5% m.v. + 3 digits) |
Fault loop ZL-PEin RCD mode | from 0.50 Ω ... 1999 Ω acc. to IEC 61557 | 0.00 Ω ... 1999 Ω | from 0.01 Ω | from ±(6% m.v. + 5 digits) |
Measurements of RCD parameters | ||||
RCD tripping test and measurement of tripping time tAmeasuring current 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn | ||||
general and short-time delay RCD | 0 ms ... 300 ms | 0 ms ... 300 ms | 1 ms | ±(2% m.v. + 2 digits) |
selective RCD | 0 ms ... 500 ms | 0 ms ... 500 ms | 1 ms | ±(2% m.v. + 2 digits) |
Measurement of RCD tripping current IAmeasuring current 0.2 IΔn ... 2.0 IΔn | ||||
for sinusoidal residual current (AC type) | 3.0 mA ... 1000 mA | 3.0 mA ... 1000 mA | from 0.1 mA | ±5% IΔn |
for unidirectional residual current and unidirectional with the 6 mA DC bias (type A | 3.5 mA ... 700 mA | 3.5 mA ... 700 mA | from 0.1 mA | ±10% IΔn |
for direct residual current (type B) | 2.0 mA ... 1000 mA | 2.0 mA ... 1000 mA | from 0.1 mA | ±10% IΔn |
Earth resistance | ||||
3-pole method | od 0.5 Ω ... 1.99 kΩ wg IEC 61557-5 | 0.00 Ω ... 1.99 kΩ | from 0.01 Ω | from ±(2% m.v. + 3 digits |
Insulation resistance | ||||
Measuring voltage 50 V | 50 kΩ ... 250 MΩ acc. to IEC 61557-2 | 0 kΩ ... 250 MΩ | from 1 kΩ | ±(3% m.v. + 8 digits) |
Measuring voltage 100 V | 100 kΩ ... 500 MΩ acc. to IEC 61557-2 | 0 kΩ ... 500 MΩ | from 1 kΩ | ±(3% m.v. + 8 digits) |
Measuring voltage 250 V | 250 kΩ ... 999 MΩ acc. to IEC 61557-2 | 0 kΩ ... 999 MΩ | from 1 kΩ | ±(3% m.v. + 8 digits) |
Measuring voltage 500 V | 500 kΩ ... 2,00 GΩ acc. to IEC 61557-2 | 0 kΩ ... 2,00 GΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 1000 V | 1000 kΩ ... 3,00 GΩ acc. to IEC 61557-2 | 0 kΩ ... 3,00 GΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Measuring voltage 2500 V | 2.50 MΩ ... 9.99 GΩ acc. to IEC 61557-2 | 0 kΩ ... 9,99 GΩ | from 1 kΩ | from ±(3% m.v. + 8 digits) |
Resistance of protective conductors and equipotential bondings | ||||
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current | 0.12 Ω ... 400 Ω acc. to IEC 61557-4 | 0.00 Ω ... 400 Ω | from 0.01 Ω | ±(2% m.v. + 3 digits) |
Measurement of resistance with low current | 0.0 Ω ... 1999 Ω | 0.0 Ω ... 1999 Ω | from 0.1 Ω | ±(3% m.v. + 3 digits) |
Phase sequence indication | in the same direction (correct). opposite direction (incorrect). UL-Lvoltage: 95 V ... 500 V (45 Hz ... 65 Hz) |
Reviews
Leave a review of this product!
If you've used this product, please leave a review to tell us and other customers what you thought about it. Get paid up to $16 for submitting one of the first text, photo, or video reviews for this item. Please contact us for more details.
Write a text review
Earn $2.00Post a product photo
Earn $4.00Post a product video
Earn $10.00