Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer

  • Part #:WMGBTDR420
  • Model #:TDR-420
  • Condition:Brand New
0 Reviews Write a Review
Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer
Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer
Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer
Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer
Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer
Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer
Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer
Fault Locators and Cable Tracers Sonel WMGBTDR420 TDR-420 Time Domain Reflectometer
    • $2,419.27 / Each
  • Free Shipping logoFree Shipping
See product details
3-4 Weeks Factory Lead Time
Check Availability
Quantity:
Technical details
Measuring ranges20, 45, 90, 180, 360, 750, 1500, 3000, 6000, 10000, 20000 [ft] 7 m, 15 m, 30 m, 60 m, 120 m, 250 m, 500 m, 1 km, 2 km, 3 km, 6 km
Accuracy1% of selected range
Resolutionapprox. 1% of range
Minimum cable length4 m
Velocity of propagationwithin 10…99% or 15…148.5 m/μs
Output impulse5 Vp-p for an open circuit
Output impedance25, 50, 75, 100, 125 and 200 Ω
Impulse width3 ns…3 μs (depending on the range)
Scanning typeup to 3 scans/s or a single scan (ONCE mode)
Generated acoustic signal810 - 1100 Hz
Operating time on a full batteryup to 8 hours of continuous scanning
Power supply4 x alkaline batteries 1.5 V AA type or 4 x NiMH AA rechargeable batteries
Auto-off function1, 5, 10, 15 minutes or deactivated
Displaycolour 3.5" LCD TFT, 320 x 240 pixels
Overvoltage protection400 V DC / 250 V AC
Operating temperature-20...+70°C | -4...+158°F
Storage temperature-30°...+80°C | -22...+176°F
Electromagnetic compatibility standards (EMC)EN 61326-1
Degree of protection / tightnessIP67