Technical details

Insulation resistance measurement

Measurement range acc. to EN IEC 61557-2 forISOmin=UISOnom/IISOnom…≤ 2 TΩ (IISO=1.6 mA) („m.v." - measured value)

RangeResolution / Accuracy
0.0...999.9 kΩ0.1 kΩ / ±(3% m.v. + 20 digits)
1.000...9.999 MΩ0.001 MΩ / ±(3% m.v. + 20 digits)
10.00...99.99 MΩ0.01 MΩ / ±(3% m.v. + 20 digits)
100.0...999.9 MΩ0.1 MΩ / ±(3% m.v. + 20 digits)
1.000...9.999 GΩ0.001 GΩ / ±(3% m.v. + 20 digits)
10.00...99.99 GΩ0.01 GΩ / ±(3% m.v. + 20 digits)
100.0...999.9 GΩ0.1 GΩ / ±(3% m.v. + 20 digits)
1.000...2.000 TΩ0.001 TΩ / ±(3% m.v. + 20 digits)

Values of measured resistance depending on measurement voltage

Voltage UnMeasurement range
10 V10 GΩ
25 V20 GΩ
50 V50 GΩ
100 V100 GΩ
250 V250 GΩ
500 V500 GΩ
1000 V1.00 TΩ
2500 V2.00 TΩ

DC and AC voltage measurement (frequency range: 45…65 Hz)

RangeResolution / Accuracy
0…1500 V1 V / ±(3% m.v. + 2 digits)

Capacitance measurement

RangeResolution / Accuracy
0...999 nF1 nF / ±(5% m.v. + 5 digits)
1.00...9.99 μF0.01 μF / ±(5% m.v. + 5 digits)

Continuity test with current 200 mA (Measurement range acc. to EN IEC 61557-2: 0.10...999 Ω)

RangeResolution / Accuracy
0.00…19.99 Ω0.01 Ω / ±(2% m.v. + 3 digits)
20.0…199.9 Ω0.1 Ω / ±(2% m.v. + 3 digits)
200…999 Ω1 Ω / ±(2% m.v. + 3 digits)

Temperature measurement

RangeResolution / Accuracy
-40.0…99.9°C0.1°C / ±(3% m.v. + 8 digits)
-40.0…211.8°F0.1°F / ±(3% m.v. + 16 digits)

Insulation resistance measurement in EPA areas

RangeResolution / Accuracy
for Un = 10 V 
0.0…999.9 kΩ0.1 kΩ / ±(8% m.v. + 20 digits)
1.0…9.999 MΩ0.001 MΩ / ±(8% m.v. + 20 digits)
10.00…99.99 MΩ0.01 MΩ / ±(8% m.v. + 20 digits)
100.0…999.9 MΩ0.1 MΩ / ±(8% m.v. + 20 digits)
1.0…10.0 GΩ0.1 GΩ / ±(8% m.v. + 20 digits)
for Un = 100 V 
0.0…999.9 kΩ0.1 kΩ / ±(3% m.v. + 20 digits)
1.000…9.999 MΩ0.001 MΩ / ±(3% m.v. + 20 digits)
10.00…99.99 MΩ0.01 MΩ / ±(3% m.v. + 20 digits)
100.0…999.9 MΩ0.1 MΩ / ±(3% m.v. + 20 digits)
1.000…9.999 GΩ0.001 GΩ / ±(3% m.v. + 20 digits)
10.00…99.99 GΩ0.01 GΩ / ±(3% m.v. + 20 digits)
100.0…200.0 GΩ0.1 GΩ / ±(8% m.v. + 20 digits)
for Un = 500 V 
0.0…999.9 kΩ0.1 kΩ / ±(3% m.v. + 20 digits)
1.000…9.999 MΩ0.001 MΩ / ±(3% m.v. + 20 digits)
10.00…99.99 MΩ0.01 MΩ / ±(3% m.v. + 20 digits)
100.0…999.9 MΩ0.1 MΩ / ±(3% m.v. + 20 digits)
1.000…9.999 GΩ0.001 GΩ / ±(3% m.v. + 20 digits)
10.00…9999 GΩ0.01 GΩ / ±(3% m.v. + 20 digits)
100.0…999.9 GΩ0.1 GΩ / ±(8% m.v. + 20 digits)
1000 GΩ1 GΩ / ±(8% m.v. + 20 digits)