PCE Instruments PCE-PCM 3 Digital Multimeter for Single-Phase Measurement

  • Part #:PCE-PCM 3
  • Condition:Brand New
0 Reviews Write a Review
  • List Price: $303.00
    • $287.85 / Each
      You Save: 5.0%
  • Free Shipping logoFree Shipping
See product details
Technical details

Ambient conditions 23°C / 73.4°F ± 5°C / 41°F, < 75% RH

Measuring function  
Current measurement AC  
Measuring rangeResolutionAccuracy
60 A0.01 A± 2% + 8 Dgt
600 A0.1 A± 2% + 8 Dgt
1000 A1 A± 2% + 8 Dgt
   
Maximum input current: 1000 A AC
Frequency range: 40 .... 400 Hz
   
Measuring function  
Inrush current AC  
Measuring rangeResolutionAccuracy
60 A0.01 AFor reference only
600 A0.1 A± 5% + 60 Dgt
1000 A1 A± 5% + 60 Dgt
   
Integral time: 100 ms 
Measuring range: 20 ... 1000 A 
Frequency range: 40 .... 400 Hz
   
Measuring function  
Voltage measurement DC  
Measuring rangeResolutionAccuracy
6V0.001V± 0.5% + 5 Dgt
60V0.01V± 0.5% + 5 Dgt
600V0.1V± 0.5% + 5 Dgt
1000V1V± 0.8% + 4 Dgt
   
Input impedance: 10 MΩ
Maximum input voltage: 750V AC (rms value) or 1000V DC
   
Measuring function  
Voltage measurement AC  
Measuring rangeResolutionAccuracy
6V0.001V± 0.6% + 4 Dgt
60V0.01V± 0.6% + 4 Dgt
600V0.1V± 0.6% + 4 Dgt
1000V1V± 0.8% + 4 Dgt
   
Input impedance: 10 MΩ
Maximum input voltage: 750V AC (rms value) or 1000V DC
Frequency range: 40 ... 400 Hz
   
Measuring function  
Frequency measurement with  
The current measuring function  
Measuring rangeResolutionAccuracy
99.99 Hz0.01 Hz± 1.5% + 5 Dgt
999.9 Hz0.1 Hz± 1.5% + 5 Dgt
   
Measuring range: 10 ... 1 kHz
Measuring range of the input signal: > 20 AAC (rms value)
The input current increases with the measuring frequency.
Maximum input current: 1000 AAC (rms value)
   
Measuring function  
Frequency measurement with the  
Voltage measurement function  
Measuring rangeResolutionAccuracy
99.99 Hz0.01 Hz± 1.5% + 5 Dgt
999.9 Hz0.1 Hz± 1.5% + 5 Dgt
9,999 kHz0.001 kHz± 1.5% + 5 Dgt
   
Measuring range: 10 ... 10 kHz
Measuring range of the input signal: > 1V AC (rms value)
The input current increases with the measuring frequency.
Maximum input voltage: 1000V AC (rms value)
   
Measuring function  
Frequency measurement   
Measuring rangeResolutionAccuracy
9,999 Hz0.001 Hz± 0.3% + 5 Dgt
99.99 Hz0.01 Hz± 0.3% + 5 Dgt
9,999 kHz0.1 Hz± 0.3% + 5 Dgt
999.9 Hz0.001 kHz± 0.3% + 5 Dgt
99.99 kHz0.01 kHz± 0.3% + 5 Dgt
999.9 kHz0.1 kHz± 0.3% + 5 Dgt
9,999 MHz0.001 MHz± 0.3% + 5 Dgt
   
Overvoltage protection: 1000V DC or 750V AC (rms value)
Range of voltage input> 2V
(as the input voltage increases, so does the frequency)
   
Measuring function  
Duty cycle  
Measuring rangeResolutionAccuracy
0.1 ... 99.9%0.1%± 0.3% + 5 Dgt
   
Frequency range: 10 ... 10 kHz
Voltage range: 2 ... 250V AC (rms value)
(The voltage increases with the frequency)
 
Duty cycle with theFrequency range: 10 ... 1 kHz
Current measurement functionInput current: 20 ... 1000 AAC (rms value)
 
Duty cycle with theFrequency range: 10 ... 1 kHz
Voltage measurement functionInput current: 1 ... 750V AC (rms value)
 Input impedance: 1MΩ
   
Measuring function  
Resistivity  
Measuring rangeResolutionAccuracy
600 Ω0.1 Ω± 0.8% + 3 Dgt
6 kΩ0.001 kΩ± 0.8% + 3 Dgt
60 kΩ0.01 kΩ± 0.8% + 3 Dgt
600 kΩ0.1 kΩ± 0.8% + 3 Dgt
6 MΩ0.001 MΩ± 2% + 5 Dgt
60 MΩ0.1 MΩ± 2% + 5 Dgt
   
Measuring voltage: approx. 0.78V
Overvoltage protection: 750V DC, 1000V AC (rms value)
   
Measuring function  
Continuity test  
Measuring rangeResolutionAccuracy
600 Ω0.1 Ω-
   
Acoustic signal at < 50 Ω
Test voltage: 1.48V
Overvoltage protection: 750V DC, 1000V AC (rms value)
   
Measuring function  
Capacitance measurement  
Measuring rangeResolutionAccuracy
9.999 nF0.001 nF± 3% + 5 Dgt
99.99 n.f.0.01 nF± 3% + 5 Dgt
999.9 nF0.1 nF± 3% + 5 Dgt
9.999 μF0.001 μF± 3% + 5 Dgt
99.99 μF0.01 μF± 3% + 5 Dgt
999.9 μF0.1 μF± 3% + 5 Dgt
9,999mF0.001 mF± 3% + 5 Dgt
99.99 mF0.01 mF± 3% + 5 Dgt
   
Overvoltage protection: 750V DC, 1000V AC (rms value)
   
Measuring function  
Diode measurement  
Measuring rangeResolutionAccuracy
3V 0.001V-
   
DC anode side: approx. 1-mA
DC cathode side: approx. 3.2V
Overvoltage protection: 750V DC, 1000V AC (rms value)
   
Measuring function  
Single phase power measurement  
Measuring rangeResolutionAccuracy
3 W / VA / Var0.01 W / VA / Var± 3% + 5 Dgt
100 W / VA / Var0.1 W / VA / Var± 3% + 5 Dgt
4000 W / VA / Var1 W / VA / Var± 3% + 5 Dgt
10 kW / VA / var0.01 kW / VA / Var± 3% + 5 Dgt
100 kW / VA / var0.1 kW / VA / Var± 3% + 5 Dgt
750 kW / VA / var1 kW / VA / Var± 3% + 5 Dgt
   
Smallest measuring current: 1-mA
Smallest measuring voltage: 1V
   
Measuring function  
Power factor capacitive / inductive  
Measuring rangeResolutionAccuracy
0.1 ... 10.001± 5% + 5 Dgt
   
Smallest measuring current: 1-mA
Smallest measuring voltage: 1V
   
Measuring function  
Harmonics measurement  
Measuring rangeResolutionAccuracy
1-± 3% + 10 Dgt
2 ... 6-± 3.5% + 10 Dgt
7 ... 8-± 4.5% + 10 Dgt
9 ... 10-± 5% + 10 Dgt
11 ... 15-± 7% + 10 Dgt
16 ... 20-± 10% + 10 Dgt
Smallest measuring current: 1-mA
Smallest measuring voltage: 1V
The resolution depends on the voltage measuring range
   
General specifications  
Measuring rangeAutomatically and manually adjustable
Maximum voltage range1000V DC or 750V AC
Maximum working height2000 m / 6561 ft
DisplayLCD
Maximum display5999 Dgt.
Overrange"OIL"
Measuring range underflow"-OL"
Measuring rate3 Hz
Automatic shutdownAfter 30 minutes
Power supply9V block battery
Battery indicatorIcon if the battery voltage is too low
Temperature coefficient0.1 x accuracy x °C / °F*
Operating conditions0 ... 40°C, 32 ... 104°F
Storage conditions-10 ... 60°C, 14 ... 140°F
Dimensions238 x 92 x 50 mm / 9.4 x 3.6 x 2 in  
WeightAbout 420 g / < 1 lb (with batteries)
  
Accuracies are given at ambient conditions of 18 ... 28°C / 65 ... 83°F.
*The temperature is the difference between the temperature of the operating conditions and the current ambient temperature.
  
Example: 
Is the current ambient temperature greater than the temperature of the operating conditions
(50°C / 122°F (current ambient temperature)) - (40°C / 104°F (operating temperature) 
= 10°C / 50°F
Is the current ambient temperature less than the temperature of the operating conditions
(0°C (operating temperature)) - (-5°C / 23°F (current ambient temperature)) 
= 5°C / 41°F