Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface

  • Part #:PCE-CTI 10
  • Condition:Brand New
0 Reviews Write a Review
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
Voltmeters PCE Instruments PCE-CTI 10 Voltmeter with Bluetooth 4.0 Interface
  • List Price: $480.00
    • $456.00 / Each
      You Save: 5.0%
  • Free Shipping logoFree Shipping
See product details
Typically In Stock
Check Availability
Quantity:
Technical details
DC voltage 
Measuring range±600.0 mV
Resolution0.1 mV
Accuracy±(0.8 % of measured value + 8 digits)
Measuring range±6.000 V
Resolution0.001 V
Accuracy±(0.5 % of measured value + 5 digits)
Measuring range±60.00 V
Resolution0.01 V
Accuracy±(0.5 % of measured value + 5 digits)
Measuring range± 600.0 V
Resolution0.1 V
Accuracy±(0.8 % of measured value + 5 digits)
Measuring range±1500 V
Resolution1 V
Accuracy±(0.8 % of measured value + 5 digits)
  
Input impedance: >10 MΩ; Overvoltage protection: 1500 VDC / 1000 VAC rms
  
AC voltage 
Measuring range0.000 ... 6.000 V
Resolution0.001 V
Accuracy50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)
 61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)
Measuring range0.00 ... 60.00 V
Resolution0.01 V
Accuracy50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)
 61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)
Measuring range0.0 ... 600.0 V
Resolution0.1 V
Accuracy50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)
 61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)
Measuring range0 ... 1500 V
Resolution1 V
Accuracy50 ... 60 Hz: ±(1.2 % of measured value + 5 digits)
 61 ... 1 kHz: ±(2.5 % of measured value + 5 digits)
  
The accuracy relates to 10 ... 100% of the respective measuring range
and a sine wave input impedance: >9 MΩ;
Overvoltage protection: 1000 V DC/AC RMS
The accuracy of the "PEAK" function is: ±10 % of measured value
The response time of the "PEAK" function is: 1 ms
  
AC voltage with low input impedance (LowZ)
Measuring range0.000 ... 6.000 V
Resolution0.001 V
Accuracy±(3.0 % of measured value + 40 digits)
Measuring range0.00 ... 60.00 V
Resolution0.01 V
Accuracy±(3.0 % of measured value + 40 digits)
Measuring range0.0 ... 300.0 V
Resolution0.1 V
Accuracy±(3.0 % of measured value + 40 digits)
  
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS
The accuracy relates to 10 ... 100% of the respective measuring range and a sine wave
  
DC and AC voltage (50 ... 1 kHz)
Measuring range0.000 ... 6.000 V
Resolution0.001 V
Accuracy±(2.5 % of measured value + 40 digits)
Measuring range0.00 ... 60.00 V
Resolution0.01 V
Accuracy±(2.5 % of measured value + 40 digits)
Measuring range0.0 ... 600.0 V
Resolution0.1 V
Accuracy±(2.5 % of measured value + 40 digits)
Measuring range0 ... 1000 V
Resolution1 V
Accuracy±(2.5 % of measured value + 40 digits)
  
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS
  
DC and AC voltage with low input impedance (LowZ)
Measuring range0.000 ... 6.000 V
Resolution0.001 V
Accuracy±(3.5 % of measured value + 40 digits)
Measuring range0.00 ... 60.00 V
Resolution0.01 V
Accuracy±(3.5 % of measured value + 40 digits)
Measuring range0.0 ... 300.0 V
Resolution0.1 V
Accuracy±(3.5 % of measured value + 40 digits)
  
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS
  
Non-Contacting Voltage Verification (NCV)
Detection range100 ... 1000 AC/DC
Direct current 
Measuring range±60.00 A
Resolution0.01 A
Accuracy±(3.0 % of measured value + 8 digits)
Measuring range±600.0 A
Resolution0.1 A
Accuracy±(3.0 % of measured value + 8 digits)
Measuring range±1000 A
Resolution1 A
Accuracy±(3.0 % of measured value + 8 digits)
Overload protection: 1000 A AC/DC 
  
Alternating current (50 ... 60 Hz) 
Measuring range0.00 ... 60.00 A
Resolution0.01 A
Accuracy±(2.5 % of measured value + 5 digits)
Measuring range0.0 ... 600.0 A
Resolution0.1 A
Accuracy±(2.5 % of measured value + 5 digits)
Measuring range0 ... 1000 A
Resolution1 A
Accuracy±(2.5 % of measured value + 5 digits)
  
Overload protection: 1000 A AC/DC
The accuracy relates to 10 ... 100 %
of the respective measuring range and a sine wave
The inrush current measurement is for reference only
  
AC current measurement with flexible clamp meter (50 ... 400 Hz)
Measuring range0.00 ... 30.00 A
Resolution0.01 A
Accuracy±(3.0 % of measured value + 5 digits)
Measuring range0.0 ... 300.0 A
Resolution0.1 A
Accuracy±(3.0 % of measured value + 5 digits)
Measuring range0 ... 3000 A
Resolution1 A
Accuracy±(3.0 % of measured value + 5 digits)
  
Overload protection: 1000 A AC/DC
The accuracy relates to 10 ... 100% of the respective measuring range and a sine wave
  
Resistance and continuity measurement
Measuring range0.0 ... 600.0 Ω
Resolution0.1 Ω
Accuracy±(1.0 % of measured value + 10 digits)
Measuring range0.000 ... 6.000 kΩ
Resolution0.001 kΩ
Accuracy±(0.8 % of measured value + 5 digits)
Measuring range0.00 ... 60.00 kΩ
Resolution0.01 kΩ
Accuracy±(0.8 % of measured value + 5 digits)
Measuring range0.0 ... 600.0 kΩ
Resolution0.1 kΩ
Accuracy±(0.8 % of measured value + 5 digits)
Measuring range0.000 ... 6.000 MΩ
Resolution0.001 MΩ
Accuracy±(0.8 % of measured value + 5 digits)
Measuring range0.00 ... 60.00 MΩ
Resolution0.01 MΩ
Accuracy±(2.5 % of measured value + 10 digits)
  
Continuity test acoustic signal at: <50 Ω
Overvoltage protection: 1000 V AC/DC
  
Frequency measurement 
Measuring range0.00 ... 60.00 Hz
Resolution0.01 Hz
Accuracy±(0.2 % of measured value + 5 digits)
Measuring range0.0 ... 600.0 Hz
Resolution0.1 Hz
Accuracy±(0.2 % of measured value + 5 digits)
Measuring range0.000 ... 6.000 kHz
Resolution0.001 kHz
Accuracy±(0.2 % of measured value + 5 digits)
Measuring range0.00 ... 60.00 kHz
Resolution0.01 kHz
Accuracy±(0.2 % of measured value + 5 digits)
Measuring range0.0 ... 600.0 kHz
Resolution0.1 kHz
Accuracy±(0.2 % of measured value + 5 digits)
Measuring range0.000 ... 6.000 MHz
Resolution0.001 MHz
Accuracy±(0.2 % of measured value + 5 digits)
  
Overvoltage protection: 1000 V AC/DC
Sensitivity:
>2 Vrms with a duty cycle between 20 ... 80 % and a frequency of <100 kHz
>5 Vrms with a duty cycle between 20 ... 80 % and a frequency of >100 kHz
  
Duty cycle 
Measuring range10.0 ... 90.0 %
Resolution0.1 %
Accuracy±(1.2 % of measured value + 8 digits)
  
Frequency range: 40 ... 10 kHz; Pulse amplitude
±5 V with a duration between 100 µs ... 100 mS
  
Capacity 
Measuring range0.00 ... 60.00 nF
Resolution0.01 nF
Accuracy±(3.0 % of measured value + 20 digits)
Measuring range0.0 ... 600.0 nF
Resolution0.1 nF
Accuracy±(3.0 % of measured value + 8 digits)
Measuring range0.000 ... 6.000 µF
Resolution0.001 µF
Accuracy±(3.0 % of measured value + 8 digits)
Measuring range0.00 ... 60.00 µF
Resolution0.01 µF
Accuracy±(3.0 % of measured value + 8 digits)
Measuring range0.0 ... 600.0 nF
Resolution0.1 nF
Accuracy±(3.0 % of measured value + 8 digits)
Measuring range0 ... 6000 µF
Resolution1 µF
Accuracy±(3.5 % of measured value + 20 digits)
Measuring range0.00 ... 60.00 mF
Resolution0.01 mF
Accuracyfor reference only
Measuring range0.0 ... 600.0 mF
Resolution0.1 mF
Accuracyfor reference only
  
Overvoltage protection: 1000 A AC/DC
 
Temperature measurement thermocouple Type K (connection)
Measuring range-40.0 ... 600.0 °C
Resolution0.1 °C
Accuracy±(1.5 % of measured value + 3 °C)
Measuring range600 ... 1000 °C
Resolution1 °C
Accuracy±(1.5 % of measured value + 3 °C)
Measuring range-40.0 ... 600.0 °F
Resolution0.1 °F
Accuracy±(1.5 % of measured value + 5.4 °F)
Measuring range600 ... 1800 °F
Resolution1 °F
Accuracy±(1.5 % of measured value + 5.4 °F)
Measuring range245.0 ... 600.0 K
Resolution0.1 K
Accuracy±(1.5 % of measured value + 3 K)
Measuring range600 ... 1273 K
Resolution1 K
Accuracy±(1.5 % of measured value + 3 K)
  
Overvoltage protection: 1000 A AC/DC
  
Diode test 
Test current<1.5 mA
Maximum voltage3.3 VDC
  
Further specifications 
Storage space16 groups with a total storage space
 of 100,000 measured values
Clamp diameter horizontal38 mm / 1.49"
Clamp diameter vertical63 mm / 2.48"
Clamp opening45 mm / 1.77"
Protection classIP65
InterfaceBluetooth 4.0
Pollution degree2
Insulation categoriesCAT IV 600 V, CAT III 1000 V, CAT II 1500 V
Maximum working height2000 m / 6562 ft
Power supply battery7.4 V, 1200 mAh Li-ion battery
Power supply charger     Primary: 100 ... 240 V AC, 50 ... 60 Hz
 Secondary: 12 V DC, 2 A
Plug connection chargerEuropa, USA, England, China
Battery status displayavailable
Automatic switch-offswitched off, 15, 30 or 60 minutes
Display2.36" TFT
Display frequency3 Hz
Reference conditions18 ... 28 °C, 64 ... 82 °F; <80 % RH,
 non-condensing
Dimensions275 x 100 x 45 mm / 10.8 x 3.9 x 1.7"
Weight481 g / 16.9 oz