Technical details
Voltage measurement | 4.0 ... 600.0 V RMS value ± 0.5% of the measured value ± 5 digits / 0.1 V |
Voltage peaks (> 10V) | 50 Hz - 60 Hz / ± 5% ± 50 digits |
Current measurements | 4.0 ... 1500.0 A real ± 1% V. of the measured value ± 5 digits / 0.01 A |
Current peaks (> 20A) | 50 Hz - 60 Hz / ± 5% ± 50 digits |
Active power P | 10 W ... 9999 kW in 5 measurement ranges ± 1% of the value + 20 digits (>20 V y >20 A) ± 2% of the value + 40 digits (>20 V y >20 A) 0.1 W ... 1 kW according to the measurement range |
Apparent power S | 10 VA ... 9999 kVA in 5 measurement ranges ± 1% of the value + 20 digits (>20 V y >20 A) ± 2% of the value + 40 digits (>20 V y >20 A) 0.1 VA ... 1 kVA according to the measurement range |
Reactive power Q | 10 VAr ... 9999 kVAr in 5 measurements ranges ± 1% of the value + 20 digits (>20 V y >20 A) ± 2% of the value + 40 digits (>20 V y >20 A) 0.1 VAr ... 1 kVAr according to the measurement range |
PF power factor | 0.000 ... 1.000 ± 0.04 (>20 V >20 A) / 0,001 ± 0.1 (>20 V >20 A) / 0,001 |
Phase angle | -180 ... +180 / ±1 / 0,1 0 ... +360 / ±1 / 0,1 |
Frequency measurement (U > 50 V) | 46 ... 65 Hz ±0.3 Hz / 0.1 Hz |
Active energy | 0 ... 999.999 kWh ± 1% of the value + 20 digits |
Apparent energy | 0 ... 999.999 kVAh ± 1% of the value + 20 digits |
Reactive energy | 0 ... 999.999 kVarh ± 1% of the value + 20 digits |
Harmonics in the voltage (relative) 50 - 60 Hz > 80 V AC | 1 - 20 th / ± 2% / 0.1% 21 - 50 th / ± 4% of the value ± 2% / 0.1% |
Harmonics in the voltage (absolute) 50 - 60 Hz > 80 V AC | 1 - 20 th / ± 2% / 0.1% 21 - 50 th / ± 4% of the value ± 0.5% / 0.1% |
Harmonics in the current (relative) 50 - 60 Hz > 80 V AC | 1 - 20 th / ± 2% / 0.1 % 21 - 50 th / ± 4% of the value ± 2% / 0.1 % |
Harmonics in the current (absolute) 50 - 60 Hz > 80 V AC | 1 - 20 th / ± 2% of the value ± 0.4 A / 0.1 A 21 - 50 th / ± 4% of the value ± 0.4 A / 0.1 A |
Total harmonic distortion (THD-F) 50 - 60 Hz > 80 V y > 20 A | 0.0 - 20% / 2% / 0.1% 20.1 - 100% / ± 6% of the value ± 1% / 0.1% 100.1 - 999.9 % / ± 10% of the value ± 1% / 0.1% |
Max. clamp opening | 55 mm / 2.2 in |
Range selection | Auto |
Overload indication | "OL = Overload |
Memory | 50,000 readings |
Interface | USB |
Software and data cable | included in the delivery. They can be used with Win 2000, XP, ME |
Display | graphic LCD display, 128 x 64 with backlight |
Power supply | 2x 1.5V AA batteries |
Energy consumption | Approx. 10-mA |
Dimensions | 271 x 112 x 46 mm / 10.6 x 4.4 x 1.8 in |
Weight | 650 g / 1.4 lbs with batteries |
Operating conditions | 85% max. R.H. / -10 ... 50°C / 14 ... 122°F |
Protection / Standards | CAT III 600 V / EN 61010-2-032 |